中文版  |  English
 
Product
Product
Series of high-temperature resistant rock wool products —— ·Panel ·Pipe
Brief Introduction
  Series of High-Temperature Resistant Rock Wool Products are the new generation rock wool products which our enterprise has developed specially for the ship application of A-60 grade fire division. The main material is basalt. They resulted from thread to fiber by means of high-speed centrifugal. Compared with the ordinary rock wool prductions,our fireproof temperature has already reached the test of the ship A-60 grade fire division.Compared with the ceramic fiber,these series hold the advantage for people to avoid the danger of absorbing the thin fiber.These products have filled the domestic gaps,and reached the international level And they have patented as well.
The whole series of products
1. High-temperature resistant rock wool panel
2. High-temperature resistant rock wool pipe
3. High-temperature resistant rock wool blanket
 
Drawing of construction of high-temperature resistant
rock wool fireproof deck(Type:A60-D4)
Drawing of construction of high-temperature resistant
rock wool fireproof bulkhead(Type:A60-B4)
 
Characterisitic/Function
Item Data Remark
Density(㎏/m3) 45~150 Processing according to customer's requirement
Fiber average diameter (μm) ≤7.0 GB5480.4
Dregs content (%) ≤10.0 Φ>0.25㎜、GB5480.5
Temperature for shrinkage under hot load (℃) ≥700 P=490,The temperature that 10 ercent of it is shrinked
Organic matter content(%) Panel、belt Pipe Felt GB/T11835 Appendix E
≤3.0 ≤4.0 ≤1.5
Moistrue resistivity (%) ≥98.0 GB10299
Hydroscopicity(%) ≤5.0 GB5480.7
Heat conductivity coefficient (W/m·K) ≤0.044 Mean temperature
Sound absorptivity 0.09~0.94 125~4000HZ
Non-combustibility Pass IMO.A799(19)
Ion content in lixivium Pass GB/T17393
Acidity coefficient ≥1.7 (SiO2+Al2O3)/(CaO+MgO)
A-60 grade fire division The material of prescriptive structures has reached the best of A-60 grade fire division IMO.FTPC Part3
/IMO.A754(18)
 
Selection table for casing pipes
Medium temperature 100 150 200 250 300 350 400 500 600
Outside temperature≤55℃
Normal diameter(mm) Exermal diameter of tube (mm) Thickness(mm)
Felt or slab density 100~150kg/m3    Half tube density 150~200kg/m3
15~65 22~73 30 30 30 30 30 40 50 60 70
65~100 73~108 30 30 30 30 30 40 50 60 70
125 133 30 30 30 30 30 40 50 60 70
150 159 30 30 30 30 40 40 50 60 70
200 219 30 30 30 30 40 50 50 60 70
250 273 30 30 30 30 40 50 60 60 70
300 325 30 30 30 30 40 50 60 70 70
350 377 30 30 30 30 40 50 60 70 80
400 426 30 30 30 40 40 50 60 70 80
450 478 30 30 30 40 50 50 60 70 80
500 529 30 30 30 40 50 60 60 70 80
600 630 30 30 30 40 50 60 70 70 80
700 720 30 30 40 40 50 60 70 80 80
800 820 30 30 40 50 50 60 70 80 90
900 920 30 30 40 50 50 60 70 80 90
1000 1020 30 30 40 50 50 60 70 80 90
REMARKS:
1.Felt and slab is suggested to be used for diameter<400mm; half tube is generally used for diameter>400mm.
2.Pleas refer to the chart for proposed casing and covering of insulation pipes; It is preferable to follow heat insulation calculations made by design units.
3.The application of temperature of XN-4 rock wool pipes is 450℃ below; the application of temperature of XN-5 high-temperature rock wool pipes is 600℃ below.
 
Refractory Material   ·   Heat Insulation Material   ·   Cold Insulation Material   ·   Sound Insulation Material   ·   Anti-corrosion Project
Copyright: NINGBO HUANYU FIRE-PROOF MATERIAL CO.,LTD. Add: Yuetouzui Danxi Street, Xiangshan, Ningbo, Zhejiang, China  
P.c: 315711 Tel:86-574-65791666 65790196  Fax:86-574-65790195 65790028  E-mail:nbhuanyu@163.com